The Dual Fuel Range Cooker With 13amp Plug Mistake That Every Beginner Makes
Dual Fuel Range Cooker With 13amp Plug Are you a home cook who loves the flexibility of gas cooktops but needs an oven for baking? Discover a dual-fuel range cooktop that gives you the best of both worlds. Gas cooktops are favored by many home chefs with expertise in the kitchen due to their superior temperature control. They also permit them to utilize advanced cooking techniques, such as charcoaling. These powerful stoves are expensive particularly if they require an extra gas connection and an electrician for installation. What is a 13amp outlet? If you have a dual fuel range cooker (also known as a gas and electric oven), then you'll need an appropriately rated 13 amp plug. The plug must also be hard-wired by a certified electrician to the cooker ring. This ensures that the current flowing through the plug is safe and not too high, which could create an electrical fire risk. The current is controlled by a fuse in the plug. The fuse goes out as soon as the current flows through it beyond its capacity, which protects the appliance from overload of electricity. The fuse is rated at 13 amps, which is shown on top of the plug. This indicates the maximum amount of current that the plug could pass without damaging the appliance or heating the socket. When replacing fuses, it's essential to use the same amp rating as the original. There is a risk of overheating a socket when you replace a fuse with a different rating. Ceramic 13 amp fuses are extremely durable, and can withstand the high temperatures that can be generated by the range cooker. Ceramic is also fire-proof, making it a more suitable choice over other types of fuse. There are many ways that 13 amp plugs can be installed. The plug can be connected to a live socket with a screw or plastic jaw cord clamp. The clamp must be tightened after the plug is securely pushed into position. Some plugs include a wiring diagram on cardboard over the pins, and these must be removed prior to connecting the wires. The wires should be cut to the proper length, as when they are too long they can get crushed when the plug covers are replaced. The earth wire must be the longest in order to connect it prior to the neutral and line pins. How do I install an outlet with 13amps? The vast majority dual cookers that use fuel in the UK are powered by an amp rating of 13 amps. This is important because ovens draw a large amounts of current, while normal plug sockets have a 10 amp rating. In general new appliances must be fitted with a plug at the point of sale. This is to ensure compliance with the Plugs and Sockets etc. (Safety Regulations) 1994. However, older appliances might not be connected to an outlet and that is the reason why the problem occurs. When connecting a cooker to an existing plug socket, the first step is to ensure that the rating of the fuse in the box is in line with the plug's rating. This is crucial because a fuse that is not properly sized could pose a risk. It is also recommended to check that the fuse is fully seated in the cartridge, and that there is no excessive movement. The next step is to prepare the flex to be used. Remove the sheathing to expose the three insulated conductors. Next nick the sheathing at the point of entry to the plug (beyond the cord grip) using a utility knife without penetrating the individual conductors that are insulated. The nick should be large enough to allow the sheathing and cable to separate as the sheathing is pulled back. Finally cut off the excess sheathing and leave about 40mm over the flexing end. This flex is placed over the plug, with the earth terminal at the top and the live and neutral terminals at the bottom. Using the coloured conductors to guide you, the sheathing is then removed from each pin and the internal cable is fixed into the appropriate terminal using the cord grip. If the plug is equipped with a clamp for cords that is screw-type, let it loosen and then pull the insulation back to expose the copper wires. Connect each insulated wire to the correct terminal by using the channel inside the plug. Begin with the earth conductor, then the neutral, and then the live. What is the maximum draw of a plug with 13amps? The maximum current draw for a 13amp plug at 300 volts is 3kw. This is quite a bit of power, but the standard fuse in a UK plug will not fail until the cable is heated to a risky temperature. A faulty plug or socket could cause fire, so it's important to be vigilant about the amount of power you use particularly in the kitchen. The fuses in plugtops are ceramic, approximately 25mm in length and 240V mains rated. They will have a BS kitemark or similar mark on the side and will contain sand. Plastic or glass alternatives are available, but should never be used in combination with a live plug. Most dual fuel range cookers in the UK require hard-wired and will not plug directly into a wall socket. They are usually connected to a dedicated cooker ring circuit, which is only suitable for appliances that draw up to 20 amps. Check the ring circuit of your home by using the fuse box, or contact an electrician in your area. They will be able tell you if the sockets within your home are connected to the same ring, or if they are separate and if there is a separate circuit for your oven. If you're in the market for a brand new dual fuel range cooker the size of your kitchen is a crucial aspect to take into consideration. We have a wide choice of cookers to fit any space, including small 50-60cm dual fuel models, as well as massive 90cm+ double oven options from the top brands such as Rangemaster and StovesAreUs. We also have a wide range of multifunction electric and gas cookers. These multifunction cookers allow you to cook a variety of meals like pasta, casseroles and curries. Explore our full range of Cookers in Currys on our website or visit us in store for a look. We offer free delivery and installation at home on selected range cookers, as well as flexible payment options. Our team is available to answer any questions you might have. Contact duel fuel range via email or by phone. Credit is subjected to the status of the account, and terms and condition apply. What is the maximum current draw of the cooker switch? There is a lot of confusion about the maximum current draw for the cooker switch. The majority of cookers are hard-wired and connected to an oven-ring circuit, not an ordinary socket. This is because they often draw more than 20 amps of power each time the gas hob and electric oven are in use. So, you won't find a dual fuel range cooker that can be connected to a standard socket because this could create a serious fire risk and would be against electrical safety regulations. A licensed electrician should install new electrical circuits in the kitchen, connecting them to an oven. They should also ensure that the load of the oven and hob do not exceed the circuit's supply capacity. The benefits of a dual fuel cooker are the responsive heating of a gas cooktop along with the precision of an electric oven. This is why they are highly sought-after by chefs and cooks at home alike. Dual cookers that use fuel are great for trying out different cooking techniques, including searing or grilling. When buying a new cooktop, you must take into consideration a variety of factors such as size, function and cost. You will also need an electrical connection to your home to allow the appliance. If you're unsure then it's advisable to have a Gas Safe engineer inspect your home prior to installing. The Currys range of dual fuel range cookers has options to fit a variety of budgets, from affordable models from Indesit and Zanussi to our own exclusive Essentials collection. If you are seeking something more sophisticated, we stock a variety of top JennAir models, which feature a number new features. When you purchase a new dual fuel range cooker, it is crucial to consult the manual of the owner for specific details on the electrical and gas requirements. You will require a gas connection in your home. A plumber may be required to install it for you. You might also require an individual cooker-ring circuit installed by a qualified electrical engineer.